Related Experiment Video
Updated: Aug 20, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
How does indirect air-cooling influence pulp chamber temperature in different volume teeth and absence/presence of
Mathieu Mouhat1, Lina Stangvaltaite-Mouhat2, Emil Finnäs3
1Department of Clinical Dentistry, Faculty of Health Sciences, UiT The Arctic University of Norway, Tromsø, Norway. mathieu.mouhat@uit.no.
Background:
Light-curing of materials during restorative dental procedures poses a risk for pulp tissue overheating. Therefore, the aim of this study was to investigate the effect of indirect air-cooling on pulp chamber temperatures during light-curing of varying volume teeth and absence/presence of resin-based composite (RBC) at different exposure time.
Methods:
The volume of 11 human teeth was measured by micro computed tomograph. An experimental rig controlled the thermal environment of the teeth and a thermocouple inserted retrograde into the root canal measured temperature changes. Pulp chamber temperature was measured with and without air-cooling on teeth without and with RBC at 15 s, 30 s and 60 s intervals. Generalized estimating equations were used for statistical analysis.
Results:
The temperature increase with air-cooling (versus no air-cooling) was lower in teeth despite absence/presence of RBC (β = - 4.26, 95%CI - 5.33 and β = - 4.47, 95%CI - 5.60, respectively). With air-cooling, the temperature increase in teeth with RBC was lower compared to teeth without RBC (β = - 0.42, 95%CI -0.79; - 0.05). Higher teeth volume resulted in lower temperature increase with air-cooling than without air-cooling (β = - 0.04, 95%CI -0.07; - 0.01 and β = - 0.17, 95%CI -0.30; - 0.05, respectively).
Conclusions:
Air-cooling resulted in lower pulp chamber temperature increase. Using air-cooling, the temperature increase was lower in teeth with RBC compared to teeth without RBC. Lower volume teeth resulted in higher temperature increase, thus they seemed to benefit more from air-cooling compared to higher volume teeth. Air-cooling could be an effective tool in controlling pulp temperature increase during light-curing, especially when the tooth volume is small.
More Related Videos