Experimental dataset on the residual performance of fiber-reinforced cementitious composite subjected to high
Paulo Roberto Ribeiro Soares Junior1, Priscila de Souza Maciel2, Elaine Carballo Siqueira Correa1
1Department of Materials Engineering, Federal Center for Technological Education of Minas Gerais (CEFET-MG), Avenida Amazonas, 5253, Belo Horizonte, MG 30421-169, Brasil.
Abstract:
The present dataset refers to the research article entitled "A multiscale investigation on the performance improvement of fiber-reinforced cementitious composites after exposure to high temperatures" [1]. Supplementary data on raw materials characterization, temperature recording, mass loss, water absorption, compressive strength, flexural behavior, pull-out response, fiber-matrix interface, and surface, microstructure and hardness of fibers are presented here. The continuous matrix was produced from cementitious grout containing Portland cement, sand, silica fume, superplasticizer, and water. The heating was carried out in an electric oven up to 260 °C. The bending tests was performed for fiber-reinforced cementitious composite (FRCC) with steel fiber contents of 1%, 3%, and 5% by volume, and for non-fibrous matrix. The pull-out test was performed using single fiber embedded in the matrix. The water absorption and axial compression tests was performed for non-fibrous matrix. The fiber-matrix analysis was performed from polished sections of fibers embedded in cementitious matrix. The fiber analysis was performed from steel fibers. The data refer to the residual properties after heating and slow cooling or to the reference condition without heating. The data can help in understanding residual performance of FRCC after exposure to high temperatures and may be useful for developing resilient building materials.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Related Concept Videos
Fiber Reinforced Concrete
Fatigue Strength of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Reinforcements in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...