Related Experiment Video
Updated: Aug 20, 2025

Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
High resolution dataset from a net-zero home that demonstrates zero-carbon living and transportation capacity
Borui Cui1, Sangkeun Lee1, Piljae Im1
1Oak Ridge National Laboratory, One Bethel Valley Rd. Oak Ridge, TN 37831, United States.
Abstract:
This dataset includes high resolution, detailed end use data from a net-zero occupied home that demonstrates zero-carbon living and transportation capacity. The house is located in Davis, California, U.S., and the dataset includes full year data from 2020 with 1 minute time resolution. The data has been monitored with more than 230 sensors installed in the house, and there are total 332 channels available. The data includes detailed end use electricity data (e.g., HVAC system, lighting, plug load including major appliances), building's interior thermal conditions (e.g., indoor air temperatures in multiple rooms and relative humidity), HVAC system operation data (e.g., soil temperatures around ground bores and supply water temperatures), on-site power generation system data (e.g., PV power supply and PV surface temperatures) and etc. The original dataset from the house has been curated, and the data has been carefully reviewed for quality check. The data quality check revealed there are 156 minutes of data were missing in the month of April, and around 1,404 minutes of data was missing in August. The data gap was filled with linear interpolation in case the gap is less than continuous 6 hours. Otherwise, the data is filled with -9999. The data curation has been processed using the Tsdat framework (https://github.com/tsdat/tsdat). In addition, a semantic description for the dataset was generated by leveraging the Brick (https://brickschema.org/). The final curated and processed data as well as raw data are currently available through https://bbd.labworks.org/ds/bbd/hshus.
More Related Videos
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
The Carbon Cycle
Energy Conservation and Bernoulli's Equation
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
Energy Line and Hydraulic Gradient Line
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Energy Diagrams - II
The point in the energy diagram at which the system’s potential energy is the lowest is known as the local minima. The system tends to stay in this position indefinitely unless acted upon by a net force. The slope of the potential energy diagram at the local minima is zero, indicating that zero net force is acting on the system. The...

