A UK-based ground truth data set of GCMS analysed ignitable liquid samples - a template for making chromatographic
Jonathan Miller1, Roberto Puch-Solis1, Wan Nur Syuhaila Mat Desa2
1Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Nethergate, Dundee DD2 1HD, Scotland.
Abstract:
Fire debris is often recovered as part of a fire scene investigation to determine whether an ignitable liquid might be present which may be evidence of a deliberate fire. The analysis of fire debris produces chromatograms that a forensic chemist uses to determine whether or not an ignitable liquid may be present. Currently there are very few publicly available data sets that can be used for training and statistical modelling in this area. The data set in this paper has been prepared with these two applications in mind and covers a wide range of ignitable liquids available in the UK. We created a data set of 35 ignitable liquids including petrol (gasoline), light, medium and heavy petroleum distillates (i.e diesel) from several retailers. Each ignitable liquid was systematically evaporated to produce six additional samples. Each sample was repetitively analysed to provide an overall data set of 751 analytical outputs (including chromatograms). Each data sample is expressed in multiple formats and the metadata containing any data used in the production of the samples is included. The folder and file names are designed to avoid misplacements and to manipulate folders and files systematically using computer code.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II