Related Experiment Video
Updated: Aug 20, 2025

A Comprehensive Procedure to Evaluate the In Vivo Performance of Cancer Nanomedicines
Published on: March 4, 2017
Enhanced Efficacy of Radiopharmaceuticals When Using Technetium-99m-Labeled Liposomal Agents: Synthesis and
Anfal M Alkandari1, Yasser M Alsayed2, Atallah M El-Hanbaly3
1Biophysics and Physics Department, Faculty of Science, Mansoura University, Mansoura 35516, Egypt.
Abstract:
Challenges posed by the retention of radiopharmaceuticals in unintended organs affect the quality of patient procedures when undergoing diagnostics and therapeutics. The aim of this study was to formulate a suitable tracer encapsulated in liposomes using different techniques and compounds to enhance the stability, uptake, clearance, and cytotoxic effect of the radiopharmaceutical. Cationic liposomes were prepared by a thin-film method using dipalmitoyl phosphatidylcholine (DPPC) and cholesterol. Whole-body gamma camera images were acquired of intravenously injected New Zealand rabbits. Additionally, liposomes were assessed using stability, toxicity, zeta potential, and particle size tests. In the control cases, Technetium-99m (99mTc)-sestamibi exhibited the lowest heart uptake the blood pool and delayed images compared to both 99mTc-liposomal agents. Liver and spleen uptake in the control samples with 99mTc-sestamibi increased in 1-h-delayed images, unlike with 99mTc-liposomal agents, which were decreased in delayed images. The mean maximum count in the bladder for 99mTc-sestamibi loaded liposomes 1 h post-injection was 2354.6 (±2.6%) compared to 178.4 (±0.54%) for 99mTc-sestamibi without liposomes. Liposomal encapsulation reduced the cytotoxic effect of the sestamibi. 99mTc-MIBI-cationic liposomes exhibited excellent early uptake and clearance compared to 99mTc-MIBI without liposomes. Adding cholesterol during liposome formation enhanced the stability and specificity of the targeted organs.

