Study of the Natural Crystalline Lens Characteristics Using Dual-Energy Computed Tomography
Jeffrey R Sachs1, Javier A Nahmias2, Kevin D Hiatt1
1Department of Radiology, Atrium Health Wake Forest Baptist Medical Center, 1 Medical Center Boulevard, Winston-Salem, NC 27157, USA.
Abstract:
There is a paucity of radiologic literature regarding age-related cataract, and little is known about any differences in the imaging appearance of the natural crystalline lens on computed tomography (CT) exams among different demographic groups. In this retrospective review of 198 eyes in 103 adults who underwent dual-energy computed tomography (DECT) exams of the head, regions of interest spanning 3−5 mm were placed over the center of the lens, and the x-ray attenuation of each lens was recorded in Hounsfield Units (HU) at 3 energy levels: 40 keV, 70 keV, and 190 keV. Generalized estimating equations (GEEs) were used to assess the association of clinical or demographic data with lens attenuation. The mean HU values were significantly lower for the older vs. younger group at 40 keV (GEE p-value = 0.022), but there was no significant difference at higher energy levels (p > 0.05). Mean HU values were significantly higher for females vs. males and non-whites vs. non-Hispanic whites at all 3 energy levels in bivariate and multivariable analyses (all p-value < 0.05). There was no significant association between lens attenuation and either diabetes or smoking status. The crystalline lens of females and non-whites had higher attenuation on DECT which may suggest higher density or increased concentration of materials like calcium and increased potential for cataract formation. Given the large scope of cataracts as a cause of visual impairment and the racial disparities that exist in its detection and treatment, further investigation into the role of opportunistic imaging to detect cataract formation is warranted.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...