Related Experiment Video
Updated: Aug 19, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Comparison of Dynamic Vibration Control Techniques by the GFRPU and/or LTMD System
Jae-Hyoung An1, Jun-Hyeok Song1, Hye-Sook Jang1
1Department of Architectural Engineering, Kangwon National University, Chuncheon 24341, Republic of Korea.
Abstract:
Reinforced concrete (RC) structures with non-seismic reinforcement details are vulnerable to earthquakes. This experimental study evaluates the efficiency of three techniques to alleviate the dynamic responses of existing structures: glass fiber-reinforced polyurea (GFRPU) reinforcement, a lever-typed tuned mass damper (LTMD) system, and a hybrid system of GFRPU and LTMD reinforcements. The lateral-resisting capacity and ductility of the GFRPU reinforcement specimen were enhanced by the material characteristics, and the dynamic responses were alleviated. The LTMD control specimen controlled the dynamic responses by the passive control system of the tuned mass damper (TMD), and the control forces to sustain its geometric motion were exerted on the specimen. The hybrid system was designed to control the dynamic responses by the GFRPU reinforcement and the LTMD control system. Four specimens, including an unreinforced specimen, were tested under external excitations, including the El Centro earthquake. The vibrations were more controlled in the order of the GFRPU reinforcement specimen, the LTMD control specimen, and the hybrid control specimen. The hybrid system was evaluated as excellent for seismic reinforcement, such as preventing abrupt failure with the lateral-resisting capacity and ductility of GFRPU and improving the dynamic control capacity by LTMD.
More Related Videos
Related Concept Videos
Load-frequency control
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Root-Locus Method
This system can be represented by a block...
Turbine-Governor Control