Related Experiment Video
Updated: Aug 19, 2025

Dual-Task Stroop Paradigm for Detecting Cognitive Deficits in High-Functioning Stroke Patients
Published on: December 16, 2022
Diagnostic yield of CT head in delirium and altered mental status-A systematic review and meta-analysis
Haris Akhtar1, Shazia H Chaudhry2, Émilie Bortolussi-Courval3
1Division of General Internal Medicine, Department of Medicine, McGill University Health Centre, Montreal, Canada.
Background:
CT head is commonly performed in the setting of delirium and altered mental status (AMS), with variable yield. We aimed to evaluate the yield of CT head in hospitalized patients with delirium and/or AMS across a variety of clinical settings and identify factors associated with abnormal imaging.
Methods:
We included studies in adult hospitalized patients, admitted to the emergency department (ED) and inpatient medical unit (grouped together) or the intensive care unit (ICU). Patients had a diagnosis of delirium/AMS and underwent a CT head that was classified as abnormal or not. We searched Medline, Embase and other databases (informed by PRISMA guidelines) from inception until November 11, 2021. Studies that were exclusively performed in patients with trauma or a fall were excluded. A meta-analysis of proportions was performed; the pooled proportion of abnormal CTs was estimated using a random effects model. Heterogeneity was determined via the I2 statistic. Factors associated with an abnormal CT head were summarized qualitatively.
Results:
Forty-six studies were included for analysis. The overall yield of CT head in the inpatient/ED was 13% (95% CI: 10.2%-15.9%) and in ICU was 17.4% (95% CI: 10%-26.3%), with considerable heterogeneity (I2 96% and 98% respectively). Heterogeneity was partly explained after accounting for study region, publication year, and representativeness of the target population. Yield of CT head diminished after year 2000 (19.8% vs. 11.1%) and varied widely depending on geographical region (8.4%-25.9%). The presence of focal neurological deficits was a consistent factor that increased yield.
Conclusion:
Use of CT head to diagnose the etiology of delirium and AMS varied widely and yield has declined. Guidelines and clinical decision support tools could increase the appropriate use of CT head in the diagnostic etiology of delirium/AMS.
More Related Videos
06:23The 4 Mountains Test: A Short Test of Spatial Memory with High Sensitivity for the Diagnosis of Pre-dementia Alzheimer's Disease
Published on: October 13, 2016
04:33Author Spotlight: Unveiling the Connection Between Sleep Disorders and Cognitive Symptoms in Depression
Published on: April 26, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies III: Computed Tomography