Strengthening Fetal Heart Rate Monitoring during Labor with a Standard Handheld Doppler - Implementation Experience
Devina Bajpayee1, Enisha Sarin1, Sourav Ghosh Dastidar1
1USAID Vriddhi Project, IPE Global Ltd., New Delhi, India.
Background:
India's neonatal and perinatal mortality is among the highest in the world. Intrapartum-related conditions contribute to a significant proportion of neonatal deaths and stillbirths. Fetal heart rate monitoring, a recommended norm to assess fetal well-bring, is not practiced as per standard guidelines in public health facilities. A standardized Doppler along with training on fetal heart rate monitoring was implemented across different levels of healthcare in three states.
Methods:
Facilities were selected purposively to implement the Doppler. Baseline data for 3 months were collected. Interviews of health providers and observation of labor were conducted quarterly. Data were analyzed through a comparison of baseline and intervention on a number of delivery and monitoring indicators.
Results:
Among 22,579 total deliveries, monitoring frequency increased along with increase in detection of abnormal fetal heart rate (FHR) while cesarean section and stillbirths reduced slightly. Cases never monitored reduced in the District Hospitals (7.98-2.07, P < 0.01) and in Community Health Centers (14.7-1.67, P < 0.001). Stillbirth rate reduced at the medical college (3.6-1.1, P < 0.001). Interviews with providers revealed acceptance of the device due to its reliable readings.
Conclusion:
The Doppler demonstrates acceptability and serves as a useful aid to improve intrapartum FHR monitoring.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation