Related Experiment Video
Updated: Aug 19, 2025

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Anaesthesia cart standardisation expedites supply retrieval: A simulation study with patient safety implications
Carey L Brewbaker1, Robert A Mester1, Dulaney A Wilson2
1Department of Anesthesia and Perioperative Medicine, Medical University of South Carolina, Charleston, SC, USA.
Background:
Anaesthesia providers often work at a variety of perioperative and procedural locations. However, the layout of anaesthesia supplies and equipment is often inconsistent from operating theatre to operating theatre. This lack of standardisation may create delays in identification and retrieval of supplies. The primary goal of this study was to compare the duration of time required by anaesthesia providers to identify and retrieve a list of anaesthesia supplies prior to and after standardisation of the location for anaesthesia supplies.
Methods:
In this observational simulation study, a pre-set list of ten items that may be rapidly needed when caring for patients was created. Volunteer anaesthesia providers were then timed retrieving these in two different operating theatres before and after anaesthesia cart standardisation. Cumulative time to retrieve all items was recorded in seconds. Participants were evaluated regarding mean time to compete the task before and after supply standardisation. Paired t-test were used to assess mean time to retrieve the ten items both before and after standardisation and between the two operating theatre locations. Providers were also evaluated on their familiarity with the operating theatre location, and this was assessed by chi-square tests of homogeneity. Multivariable generalised linear modelling was used to evaluate the impact of covariables on the change in time.
Results:
Data from 18 anaesthesia providers was collected. Mean (95% confidence interval) time in seconds to retrieve items was decreased by 45% after supply standardisation (105.3 [88.6, 121.9 vs 57.1 [50.8, 63.5]; p < 0.001) with a mean (95% confidence interval) reduction of 48.1 seconds (30.6, 65.6; p < 0.001). Providers who worked primarily at that location also had faster times to complete the task. In a multivariable regression model that considered both the provider's familiarity with the location and the simulation attempt (Operating theatre 1 or Operating theatre 2), the mean time to retrieve all items remained reduced by 48.1 seconds (95% confidence interval: 31.9-64.4) after supply standardisation (p < 0.001).
Conclusion:
Standardisation of the location for anaesthesia supplies decreased the time for on-demand item retrieval. Retrieval times were most improved after standardisation for providers in an unfamiliar area. Supply standardisation of anaesthesia carts across perioperative and procedural sites could result in more timely interventions in patient care and efficiency.
More Related Videos
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Local Anesthetics: Clinical Application as Spinal Anesthesia
Inhalational Anesthetics: Overview