Related Experiment Video
Updated: Jun 25, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Left ventricular non-compaction in paediatrics: a novel semi-automated imaging technique bridging imaging findings
Hanna J Tadros1, Tam T Doan1, Amol S Pednekar2
1Section of Cardiology, Department of Pediatrics, Baylor College of Medicine, 6651 Main St, Legacy Tower, E1920, 77030 Houston, TX, USA.
Aims:
We set out to design a reliable, semi-automated, and quantitative imaging tool using cardiac magnetic resonance (CMR) imaging that captures LV trabeculations in relation to the morphologic endocardial and epicardial surface, or perimeter-derived ratios, and assess its diagnostic and prognostic utility.
Methods And Results:
We queried our institutional database between January 2008 and December 2018. Non-compacted (NC)-to-compacted (C) (NC/C) myocardium ratios were calculated and our tool was used to calculate fractal dimension (FD), total mass ratio (TMR), and composite surface ratios (SRcomp). NC/C, FD, TMR, and SRcomp were assessed in relation to LVNC diagnosis and outcomes. Univariate hazard ratios with cut-offs were performed using clinically significant variables to find 'at-risk' patients and imaging parameters were compared in 'at-risk' patients missed by Petersen Index (PI). Ninety-six patients were included. The average time to complete the semi-automated measurements was 3.90 min (SEM: 0.06). TMR, SRcomp, and NC/C were negatively correlated with LV ejection fraction (LVEF) and positively correlated with indexed LV end-systolic volumes (iLVESVs), with TMR showing the strongest correlation with LVEF (-0.287; P = 0.005) and SRcomp with iLVESV (0.260; P = 0.011). We found 29 'at-risk' patients who were classified as non-LVNC by PI and hence, were missed. When compared with non-LVNC and 'low-risk' patients, only SRcomp differentiated between both groups (1.91 SEM 0.03 vs. 1.80 SEM 0.03; P = 0.019).
Conclusion:
This method of semi-automatic calculation of SRcomp captured changes in at-risk patients missed by standard methods, was strongly correlated with LVEF and LV systolic volumes and may better capture outcome events.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis II: Clinical features and Diagnostic Tests

