A Universal Device to Convert a Continuous Flow Assist Device to a Pulsatile Flow Device to Simulate Normal Blood
1Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
Surgical Innovation
|November 28, 2022
Summary
A novel universal converter device can transform continuous flow assist devices (CFADs) into pulsatile flow systems. This innovation aims to mimic natural blood flow patterns and potentially reduce complications associated with CFADs.
Area of Science:
- Biomedical Engineering
- Cardiovascular Devices
Background:
- Continuous flow assist devices (CFADs) are prevalent mechanical circulatory support systems.
- CFADs produce non-physiologic flow, potentially causing complications due to the lack of pulsatility.
- Lack of pulsatility complicates clinical management, leading to undetectable pulses and minimal pulse pressure.
Purpose of the Study:
- To introduce a concept for a universal converter device.
- To enable the conversion of continuous flow to pulsatile flow in existing CFADs.
- To simulate native-like flow and pressure patterns.
Main Methods:
- A conceptual inline universal converter device is proposed.
- The device features two parallel components operating in tandem.
- Specially positioned openings facilitate the conversion of continuous to pulsatile flow.
Main Results:
- The converter aims to provide the benefits of pulsatile physiologic flow after CFAD implantation.
- It can achieve a native-like flow pattern, potentially preventing CFAD-related complications.
- The device offers a method for pulsatility generation and simulation.
Conclusions:
- The presented concept offers a universal add-on solution for CFADs.
- This device can convert continuous flow to physiologic pulsatile flow.
- It has the potential to enhance patient outcomes and management.
Related Concept Videos
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Ventilatory Modes
335
Mechanical ventilators are life-saving devices that support or replace spontaneous breathing. They deliver breaths to patients through varying methods known as ventilator modes. Understanding these modes is critical for healthcare providers managing patients with respiratory failure.
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
335
Pulse rhythm
893
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
893