Related Experiment Video
Updated: Aug 19, 2025

08:18
Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
16.9K
Short-run marginal emission rates omit important impacts of electric-sector interventions
Pieter J Gagnon1, John E T Bistline2, Marcus H Alexander3
1Grid Planning and Analysis Center, National Renewable Energy Laboratory, Golden, CO 80401.
Abstract
No abstract available in PubMed .
Related Concept Videos
Power System Three-Phase Short Circuits
136
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
136
Induced Electric Fields: Applications
1.8K
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
1.8K
Atomic Emission Spectroscopy: Interference
245
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
245
Electrical Energy
1.3K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.3K
Power Factor Correction
242
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
242
Control of Power Flow
302
There are several methods to control power flow in power systems:
302

