Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Comparison of Apple Watch vs KardiaMobile: A Tale of Two Devices
Calvin Lee1, Charles Lee1, Carlos Fernando2
1Royal College of Surgeons in Ireland, Dublin, Ireland.
Background:
The Apple Watch Series 4 (AW4) and the KardiaMobile single bipolar lead model (KM) are 2 of the most popular US Food & Drug Administration (FDA)-approved commercial heart trackers. However, a lack of knowledge remains regarding their rhythm-detection accuracy in real-life clinical situations. This paper aims to determine the practicality of using an AW4 or a KM in modern medical practice, by assessing the accuracy of each in identifying heart rhythms and heart rate.
Methods:
Participants from the Toronto Heart Centre clinic were enrolled from January 2019 to December 2019. They had a 12-lead electrocardiogram (ECG), followed by wearing the AW4 watch (OS 5.3), and pressing on the KM electrode plates, within the span of 5 minutes of one another. Each session involved a 12-lead ECG, an ECG from each device, and AW4's photoplethysmography function (APPG).
Results:
Of 200 participants, 162 (81%) were in sinus rhythm, and 38 (19%) had atrial fibrillation. The rhythm-detection accuracy for sinus rhythm was 100% for the AW4, and 99.03% for the KM. For atrial fibrillation, accuracy was 90.48% for the AW4, and 100% for the KM. The heart rate accuracy for sinus rhythm was 94.39% for the KM, 90.65% for the APPG, and 96.26% for the Apple ECG function. The heart rate accuracy for atrial fibrillation was 91.30% for the KM, 82.61% for the APPG, and 86.96% for the Apple ECG function.
Conclusions:
Both the AW4 and the KM could reliably detect rhythm and heart rate in real-life clinical situations. However, a nonsignificant trend occurred toward better rhythm detection and accuracy with KM, compared with AW4. The difference is mainly due to artifacts (eg, tremors) and the fit of the strap for AW4. The findings have important implications for how these consumer devices can be used in real-life clinical settings.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement