Diagnostic value of regional myocardial flow reserve measurements using Rubidium-82 PET : Disclosures none

Sabine S Koenders1,2, Jorn A van Dalen3, Pieter L Jager4

  • 1Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands. skoenders93@gmail.com.

Abstract

Insights

Regional myocardial flow reserve (MFR) analysis of Rubidium-82 PET scans offers superior detection of obstructive coronary artery disease (oCAD) compared to global MFR. This approach enhances diagnostic accuracy for identifying oCAD.

Area of Science:

  • Cardiovascular Imaging
  • Nuclear Cardiology
  • Radiopharmaceutical PET Imaging

Background:

  • Visual assessment of Rubidium-82 (Rb-82) PET myocardial perfusion images is standard practice.
  • Global myocardial flow reserve (MFR) measurements are often combined with visual assessment.
  • Subtle regional blood flow deficits may be missed by global assessments.

Purpose of the Study:

  • To compare the diagnostic value of regional versus global MFR in detecting obstructive coronary artery disease (oCAD).
  • To evaluate the utility of Rb-82 PET/CT in identifying oCAD.

Main Methods:

  • Retrospective analysis of 1519 patients undergoing Rb-82 PET/CT for suspected oCAD.
  • MFR was calculated globally, per vessel territory, and per myocardial segment.
  • Receiver-operating characteristic analysis compared diagnostic performance against invasive coronary angiography.

Main Results:

  • Patients with oCAD showed significantly lower global, vessel, and segmental MFR compared to non-oCAD patients (p < 0.001).
  • Segmental MFR demonstrated a larger area under the curve (0.81) than global MFR (0.74) and vessel MFR (0.78), indicating superior diagnostic performance.
  • Regional MFR analysis proved more effective in identifying oCAD.

Conclusions:

  • Regional MFR analysis using Rb-82 PET/CT improves diagnostic accuracy for obstructive coronary artery disease.
  • Utilizing regional MFR is recommended over global MFR for enhanced detection of oCAD.