Related Experiment Video
Updated: Aug 19, 2025

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Computed tomography with positron emission tomography is more useful in local than systemic infectious process
M B Marciniak-Emmons1, E Świerżyńska2,3, A Mazurek4,5
12nd Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska St, 04-628, Warsaw, Poland.
Abstract:
Assess the diagnostic value of 18-F FDG PET/CT in cardiac implantable electronic devices (CIED) infections in facilitating diagnostic process and optimizing decision-making process.Study group (n = 21) patients with initial suspected diagnosis of CIED-related infection or fever of unknown origin and patients referred for device removal due to infection. Control group (n = 13) patients with implanted CIED, who underwent PET/CT due to other non-infectious indications and had no data for infectious process in follow-up.PET/CT scan showed pocket infection in 12 patients (including 1 in whom infection was not finally diagnosed-the examination was performed early after the implantation procedure-1.5 months), increased tracer uptake in intravascular lead part in 3 patients, and increased uptake in intracardiac part in 5 patients.We found that sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis made by PET/CT in generator pocket infection was 91.7%, 70%, 78.6%, 87.5% and in lead-dependent intracardiac infection 100%, 47.1%, 35.7%, 100% respectively. PET/CT scan enabled reclassification of diagnosis from possible to definite CIED-related infection in 6 out of 9 patients, and to excluded in 3 out of 9.Establishing diagnosis of device related infections may be challenging due to non-specific symptoms. Incorporation of PET/CT scan in the diagnostic schema can improve accuracy and timing of the diagnosis and help to assess the extent of infection. PET/CT is more useful in local than systemic infectious process related to cardiac implanted electrotherapy device.Trial registration Consent of the bioethics committee nr IK-NP.-0021-85/1465/14. Registration in the www.clinicaltrials.gov database: NCT02196753.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

