Related Experiment Video
Updated: Aug 19, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Hyperoxic exposure monitoring in diving: A farewell to the UPTD
Jan Risberg1, Pieter-Jan van Ooij2
1NUI, Bergen, Norway.
Abstract:
Depending on pO2 and exposure time hyperoxic breathing gas may cause injury in many organs including the lungs. Pulmonary oxygen toxicity (POT) may be asymptomatic, but will initially present as a tracheobronchitis in symptomatic subjects. A number of objective measurements of POT have been investigated, but the decrement in vital capacity (VC) has remained the most accepted outcome measure. The unit pulmonary toxic dose (UPTD) has been established as the most common exposure index for POT in diving. UPTD is calculated based on the pO2 and exposure time. A literature search identified five models predicting POT, but no model would accurately predict VC change for the full range of pO2 variation and exposure time relevant for surface-oriented diving. Nevertheless, compared to UPTD, the K-index (K = t2*pO24.57, where t = time (hours) and pO2 = inspired pO2 (atm)) suggested by Arieli performed better for pO2 > 150 kPa and allowed estimation of recovery. We recommend that the Arieli K-index should replace UPTD as the POT exposure index for all surface-oriented diving. Based on the limited data available we suggest a daily threshold of K = 120 for a maximum of two diving days followed by two days of recovery. For five consecutive days of diving, we recommend that the threshold should not exceed K=70 and two recovery days should be allowed. For multiday diving without days of recovery, the daily exposure should probably be limited to K = 40-50.
More Related Videos
11:56Training Rats to Voluntarily Dive Underwater: Investigations of the Mammalian Diving Response
Published on: November 12, 2014
07:59A Strain Gauge Monitor SGM for Continuous Valve Gape Measurements in Bivalve Molluscs in Response to Laboratory Induced Diel-cycling Hypoxia and pH
Published on: August 1, 2018
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Hyperpnea and Hyperventilation
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: