Related Experiment Video
Updated: Aug 19, 2025

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Electrophoretic mobilization in capillary isoelectric focusing by a weak acid or an acidic ampholyte as catholyte
1Institute for Infectious Diseases, University of Bern, Bern, Switzerland.
Abstract:
Capillary isoelectric focusing (CIEF) with cationic electrophoretic mobilization induced via replacing the catholyte with the anolyte or a solution of another acid or amino acid was investigated by computer simulation for a wide range pH gradient bracketed between two amphoteric spacers and short electrode vials with a higher id than the capillary. Dynamic simulations provide insight into the complexity of the mobilizing process in a hitherto inaccessible way. The electrophoretic mobilizing process begins with the penetration of the mobilizing compound through the entire capillary, is followed by a gradual or steplike decrease of pH, and ends in an environment with a non-homogenous solution of the mobilizer. Analytes do not necessarily pass the point of detection in the order of decreasing pI values. Cationic mobilization encompasses an inherent zone dispersing and refocusing process toward the capillary end. This behavior is rather strong with phosphoric acid and citric acid, moderate with aspartic acid, glutamic acid (GLU), formic acid, and acetic acid and less pronounced in the absence of the cathodic spacer. The data reveal that optical detectors should not be placed before 90% of capillary length. Aspartic acid, GLU, formic acid, and acetic acid provide an environment with a continuously decreasing pH that explains their successful use in optimized two-step CIEF protocols.
More Related Videos
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Ion-Exchange Chromatography
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...

