Related Experiment Video
Updated: Jul 29, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Association between extramural vascular invasion and iodine quantification using dual-energy computed tomography of
Wei Gao1, Yuqi Zhang2, Yana Dou3
1Department of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Huhhot, Inner Mongolia 010050, China.
Objective:
This study aimed to investigate whether histopathological confirmed extramural vascular invasion (EMVI) is associated with quantitative parameters derived from dual-energy computed tomography (DECT) of rectal cancer.
Methods:
This retrospective study included patients with rectal cancer who underwent rectal cancer surgery and DECT (including arterial-, venous-, and delay-phase scanning) between November 2019 and November 2020. The EMVI of rectal cancer was confirmed via postoperative pathological results. Iodine concentration (IC), IC normalized to the aorta (NIC), and CT attenuation values of the three phases were measured and compared between patients with and without EMVI. Receiver operating characteristic (ROC) curves were generated to determine the diagnostic performance of these DECT quantitative parameters.
Results:
Herein, 36 patients (22 men and 14 women) with a mean age of 62 [range, 43-77] years) with (n = 13) and without (n = 23) EMVI were included. Patients with EMVI exhibited significantly higher IC in the venous and delay phases (venous-phase: 2.92 ± 0.6 vs 2.34 ± 0.48; delay-phase: 2.46 ± 0.47 vs 1.88 ± 0.35) and NIC in all the three phases (arterial-phase: 0.31 ± 0.12 vs 0.24 ± 0.06; venous-phase: 0.58 ± 0.11 vs 0.41 ± 0.07; delay-phase: 0.68 ± 0.10 vs 0.46 ± 0.08) than patients without EMVI. Among them, the highest area under the ROC curve (AUC) was obtained in the delay-phase NIC (AUC = 0.983). IC in the arterial-phase and CT attenuation in all the three phases did not significantly differ between patients with and without EMVI (p = 0.205-0.869).
Conclusion:
Iodine quantification using dual-energy CT, especially the NIC of the tumor, differs between the EMVI-positive and EMVI-negative groups and seems to help predict the EMVI of rectal cancer in this preliminary study; however, a larger sample size study is warranted in the future.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography