Related Experiment Video
Updated: Aug 19, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Atraumatic Bi-femoral Axillary Bypass Graft Non-anastomotic Disruption With Pseudoaneurysm Formation Detected by
Danielle A Nesbit1, Carrie Wang1, Phillip M Grenz1
1Department of Emergency and Hospital Medicine/University of South Florida Morsani College of Medicine, Lehigh Valley Health Network, Bethlehem, USA.
Insights
Bi-femoral axillary bypass grafts can fracture, leading to complications like pseudoaneurysms. Early detection via ultrasound is crucial for prompt surgical repair and patient recovery.
Area of Science:
- Vascular Surgery
- Medical Imaging
Background:
- Bi-femoral axillary bypass grafts are standard for advanced peripheral vascular disease.
- Graft fracture or dislodgement, often at the anastomosis site, is a rare but serious complication.
Observation:
- A 68-year-old male presented with abdominal pain and a pulsatile mass.
- Initial bedside ultrasound revealed a fractured bi-femoral axillary bypass graft with a pseudoaneurysm.
Findings:
- Ultrasonography accurately identified the graft fracture and associated fluid collection.
- Emergent surgical repair was performed, followed by CT angiography confirming successful graft anastomosis.
Implications:
- Ultrasonography is vital for rapid diagnosis of bypass graft complications.
- Timely diagnosis and intervention can prevent severe outcomes and improve patient management.
Abstract:
Bi-femoral axillary bypass graft placement is a well-known and typically safe procedure. It is generally indicated for patients with advanced peripheral vascular disease, aortoiliac occlusive disease, or infectious artery disease. In rare cases, the graft can be fractured or dislodged after placement, though most often, this occurs almost exclusively at the anastomosis site, secondary to blunt trauma. Using ultrasonic imaging is a reliable method of detecting these fractures. We present a case of a bi-femoral axillary bypass graft fracture in a 68-year-old male with the development of a pseudoaneurysm in the right lateral abdominal wall. The patient reported spontaneous development of a "strange" sensation in his right lower abdomen and a "painful lump" upon waking. Physical examination showed a small right lower quadrant outpouching which was pulsatile on palpation. The initial workup included a bedside ultrasound which showed a fractured graft with the fluid collection and a Doppler signal. Vascular surgery was immediately consulted for evaluation, and the patient was taken to the operating room for emergent surgical repair. CT angiography confirmed a successful operation in which an 8 mm graft was placed to anastomose the original bypass graft fracture site. The patient remained stable postoperatively and was discharged without further complications. This report highlights the importance of using ultrasonography for the immediate identification of potential graft complications to prevent serious complications and expedite definitive management.