Related Experiment Video
Updated: Aug 19, 2025

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
The Agreement Between Virtual Patient and Unannounced Standardized Patient Assessments in Evaluating Primary Health
Minrui Zeng1, Yiyuan Cai2, Jin Cao3
1Department of Medical Statistics & Epidemiology, School of Public Health, Sun Yat-sen University, Guangzhou, China.
Background:
The unannounced standardized patient (USP) is the gold standard for primary health care (PHC) quality assessment but has many restrictions associated with high human and resource costs. Virtual patient (VP) is a valid, low-cost software option for simulating clinical scenarios and is widely used in medical education. It is unclear whether VP can be used to assess the quality of PHC.
Objective:
This study aimed to examine the agreement between VP and USP assessments of PHC quality and to identify factors influencing the VP-USP agreement.
Methods:
Eleven matched VP and USP case designs were developed based on clinical guidelines and were implemented in a convenience sample of urban PHC facilities in the capital cities of the 7 study provinces. A total of 720 USP visits were conducted, during which on-duty PHC providers who met the inclusion criteria were randomly selected by the USPs. The same providers underwent a VP assessment using the same case condition at least a week later. The VP-USP agreement was measured by the concordance correlation coefficient (CCC) for continuity scores and the weighted κ for diagnoses. Multiple linear regression was used to identify factors influencing the VP-USP agreement.
Results:
Only 146 VP scores were matched with the corresponding USP scores. The CCC for medical history was 0.37 (95% CI 0.24-0.49); for physical examination, 0.27 (95% CI 0.12-0.42); for laboratory and imaging tests, -0.03 (95% CI -0.20 to 0.14); and for treatment, 0.22 (95% CI 0.07-0.37). The weighted κ for diagnosis was 0.32 (95% CI 0.13-0.52). The multiple linear regression model indicated that the VP tests were significantly influenced by the different case conditions and the city where the test took place.
Conclusions:
There was low agreement between VPs and USPs in PHC quality assessment. This may reflect the "know-do" gap. VP test results were also influenced by different case conditions, interactive design, and usability. Modifications to VPs and the reasons for the low VP-USP agreement require further study.
More Related Videos
07:10Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Primary Healthcare Services
In 1978, international leaders convened in Alma-Ata, Kazakhstan, for what would be a pivotal event in global health. The Alma-Ata Declaration was the first to call...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Nursing Assessment
The nurse collects all aspects of the patient's health in the initial assessment, establishing priorities for ongoing focused assessments...
Assessment of the Gastrointestinal System II: Health Perception Pattern
Health Perception Patterns
Health perception patterns offer valuable insights into a patient's lifestyle habits and how they may impact their GI health. These patterns include: