Related Experiment Video
Updated: Aug 19, 2025

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Assessment of Cardiac Function and Ventricular Mechanical Synchronization in Left Bundle Branch Area Pacing by
Yingchen Mei1, Rui Han2, Liting Cheng3
1Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; Department of Cardiology, Beijing Jishuitan Hospital, Beijing, China.
Abstract:
Real-time 3-dimensional echocardiography combined with speckle tracking was used in this study. A total of 90 patients with normal left ventricular ejection fraction were divided into 3 groups according to the pacing site: left bundle branch area pacing (LBBAP), right ventricular septal pacing (RVSP) or right ventricular apical pacing (RVAP). Procedure duration (90 ± 18 vs 61 ± 6.6 vs 58 ± 5.6 minutes, p = 0.015), Fluoroscopy duration (15.5 ± 5.4 vs 4.8 ± 2.2 vs 4 ± 1.9 minutes, p = 0.004), and ventricular capture threshold at implantation (0.8 ± 0.3 vs 0.6 ± 0.2 vs 0.6 ± 0.1 V, p = 0.002) were significantly increased in patients that received LBBAP compared with RVSP or RVAP. At 4 weeks of follow-up, brain natriuretic peptide levels were significantly lower (22 [12 to 59] vs 135 [86 to 231] vs 235 [147 to 428] pg/ml, p = 0.04), paced QRS duration was significantly shorter (115 ± 26 vs 134 ± 28 vs 157 ± 29 ms, p = 0.012), and global longitudinal strain (-19.4 ± 2.4 vs -19.3 ± 3.4 vs -17.3 ± 3.5%, p = 0.026) and systolic dyssynchrony index (2.5 ± 0.3 vs 5.9 ± 0.9 vs 7.7 ± 1.2, p = 0.001), longitudinal absolute maximum difference of time to peak strain (17 [6 to 68] vs 117 [71 to 173] vs 126 [79 to 178] ms, p <0.0001), and circumferential absolute maximum difference of time to peak strain (76 [32 to 129] vs 148 [117 to 208] vs 161 [118 to 266] ms, p = 0.005) were significantly lower in patients that received LBBAP compared with RVSP or RVAP. In conclusion, LBBAP can provide a more physiological ventricular activation pattern than RVSP or RVAP and results in good left ventricular electrical and mechanical synchronization.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010