Related Experiment Video
Updated: Aug 19, 2025

Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
A 7-segment numerical hand-glove/mitten model for predicting thermophysiological responses of the human hand in
Jie Yang1, Faming Wang2, Matthew David White3
1College of Safety Science and Engineering, Xi'an University of Science and Technology, Xi'an, 710054, China.
Abstract:
A 7-segment and 29-node numerical hand-glove/mitten model was developed to simulate human hand physiological responses in various cold environments. To validate the model, simulated skin temperatures were compared to data from published literature and human trials conducted at -20, -40, and -60 °C. Results demonstrated that the model could reasonably predict cold-induced vasodilation (CIVD) responses at 0 °C temperature. At -20 °C, the model predicted skin temperature with the root mean square deviation (RMSD) falling within the measurement standard deviation (SD) for both the entire and local hand except for the posterior hand. At -40 and -60 °C, the model could predict the trend of the skin temperatures of the whole/local hand, but the RMSD was larger than the SD for the majority of predictions. A parametric analysis revealed that the palm and posterior hand had higher skin temperatures than the fingers, while the thumb had the lowest skin temperature of the fingers in all simulated cases except the case with a 3.5 clo mitten at -60 °C. The proposed numerical hand-glove/mitten model could reasonably predict local hand physiological responses in three extremely cold environments and provides fundamental knowledge for cold stress prediction and protective glove development, thereby improving the safety and health of industrial workers, firefighters, first responders, and troops.
Related Concept Videos
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Responses to Heat and Cold Stress
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...