Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation
M G Bisbee1, I Oksuz1, M P VanZile2
1Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, Ohio 43210, USA.
Abstract:
A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm-2·s-1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...