Related Experiment Video
Updated: Aug 19, 2025

Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
Characterization of commercial thermoelectric modules for precision heat flux measurement
Jacob Crossley1, A N M Taufiq Elahi1, Mohammad Ghashami2
1Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah 84112, USA.
Abstract:
In this article, we present a cost-effective approach to the precision measurement of heat flux using commercial thermoelectric modules (TEMs). Two different methods of measuring heat flux with TEMs are investigated, namely, passive mode based on the Seebeck effect and active mode based on the Peltier effect. For both modes, a TEM as a heat flux meter is calibrated to show a linear relation between the voltage across the TEM and the heat flux from 0 to ∼450 W m-2. While both modes exhibit sufficiently high sensitivities suitable for low heat flux measurement, active mode is shown to be ∼7 times more sensitive than passive mode. From the speculation on the origin of the measurement uncertainty, we propose a dual TEM scheme by operating the top TEM in passive mode while its bottom temperature maintains constant by the feedback-controlled bottom TEM. The dual TEM scheme can suppress the sensitivity uncertainty up to 3 times when compared to the single-TEM passive mode by stabilizing the bottom temperature. The response time of a 15 × 15 mm2 TEM is measured to be 8.9 ± 1.0 s for heating and 10.8 ± 0.7 s for cooling, which is slower than commercial heat flux meters but still fast enough to measure heat flux with a time resolution on the order of 10 s. We believe that the obtained results can facilitate the use of a commercial TEM for heat flux measurement in various thermal experiments.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Mechanism of heat transfer
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant...
Mechanisms of Heat Transfer I
Mechanisms of Heat Transfer II