Related Experiment Video
Updated: Aug 19, 2025

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
Published on: May 2, 2016
Novel method and instrument for temperature-dependent tensile test of metallic materials without thermometers
Yuyang Hua1, Shuo Li1, Xiaofeng Wang1
1School of Physics and Technology, Wuhan University, Wuhan 430072, Hubei, People's Republic of China.
Abstract:
A novel method for measuring temperature and conducting tensile tests of metallic wires at elevated temperatures is presented. Ohmic heating is used to elevate the sample temperature with a uniform distribution, which could vary from room temperature to its melting point. The temperatures of the wires in steady states are determined by using a heat transfer model without measuring directly by thermometers, which reduces the error introduced by contact temperature measurement or optical pyrometers. This technique for temperature measurement can be applied to measuring temperature-dependent electrical resistivity and conducting temperature-dependent tensile tests of metallic materials. A low-cost instrument was designed to conduct the tensile tests. In this work, temperature-dependent Young's modulus, tensile strength at break, and the steady-state creep rate of 99.994%-pure Pb wires were further determined as applications of the tensile tests. The results show that the proposed method is valid and very useful for conducting temperature-dependent tensile tests of metallic materials.
Related Concept Videos
Temperature Dependent Deformation
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Thermal Strain
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...