Related Experiment Video
Updated: Aug 19, 2025

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Reproducibility of skin temperature analyses by novice and experienced evaluators using infrared thermography
Willian da Silva1, Álvaro Sosa Machado1, Marcos Roberto Kunzler1
1Applied Neuromechanics Research Group, Laboratory of Neuromechanics, Federal University of Pampa, Uruguaiana, RS, Brazil.
Abstract:
Infrared thermography (IRT) has become popular in several areas of knowledge. However, the analyses of thermal images often request manual actions, and little is known about the effect of the evaluator's experience on analysis thermal images. Here, we determine the reproducibility of IRT images analysis performed by evaluators with different levels of experience. Eight evaluators (GE, group experienced, n = 4; GN, group novice, n = 4) analyzed thermograms from 40 healthy participants recorded before and after exercise to determine the mean, minimum, maximum, standard deviation, and range of skin temperature in the anterior thigh and posterior leg. Before and after exercise, mean temperature showed excellent reproducibility for both groups for the anterior thigh (ICC >0.98) and posterior leg (ICC >0.94), and maximum temperature showed excellent reproducibility for both groups in the posterior leg (ICC >0.91). The influence of experience level was not significant considering the anterior thigh. Similarly, experience level did not affect the mean, maximum, and standard deviation temperature determined for the posterior leg. For the posterior leg, minimum temperature presented lower values and the range was higher among novice evaluators. Mean skin temperature showed narrower 95% limits of agreement than minimum and maximum for both regions and moments. Caution is advised when temperature ranges and minimums are determined by different evaluators. We conclude that for IRT analysis by evaluators with different levels of experience, the mean and maximum temperatures should be prioritized due to their better reproducibility.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...