Tomotherapy: Comparison of Hi-ART, Tomo-HD, and Radixact
Hiromasa Kurosaki1, Kenta Hirayama1, Masaki Takahashi1
1Department of Radiology and Radiation Oncology, Edogawa Hospital, Tokyo, JPN.
Abstract:
Aim In this study, we compared three generations of tomotherapy (Hi-ART, Tomo-HD, and Radixact). This is to study the difference among tomotherapy systems in terms of dose distribution to planning target volume and organs at risk, and irradiation time. Materials and methods The treatment planning CT and contour information used were seven cases of rectum cancer pre-operative irradiation. The contour information used was the planning target volume, and the organs at risk were set as the bladder and body. Optimization was conducted at each planning station using the parameters that were actually used in a clinical setting. The prescribed radiation dose was 25 Gy in five fractions and normalized at the isodose line, covering 95% of the planning target volume. Results There were no significant differences in planning target volume among the three models. Meanwhile, Hi-ART had a significantly higher dose than Tomo-HD and Radixact at body D50%. Radixact shortened the irradiation time by approximately 15% compared to Hi-ART/Tomo-HD. Conclusion Planning target volume dose distribution of tomotherapy devices was not different. Radixact required a significantly shorter time than Hi-ART and Tomo-HD.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...