Nondiagnostic Test Result Rates Following Thyroid Extra-Fine-Needle Aspiration
Michael Rechter1, Sivan Saraph1, Hector Cohen2
1Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
American Journal of Clinical Pathology
|December 5, 2022
Summary
Using finer needles for thyroid fine-needle aspiration biopsy (FNAB) can increase nondiagnostic (ND) rates. A 25-gauge needle is superior to a 27-gauge needle in reducing ND rates for thyroid nodules.
Area of Science:
- Endocrinology
- Pathology
- Surgical Oncology
Background:
- The Bethesda classification system categorizes thyroid fine-needle aspiration biopsy (FNAB) results.
- Nondiagnostic (ND) results, the first category, indicate inadequate cellularity for accurate evaluation.
- Needle diameter is a potential factor influencing FNAB specimen adequacy.
Purpose of the Study:
- To investigate the impact of different needle diameters (23-, 25-, and 27-gauge) on nondiagnostic (ND) rates in thyroid FNAB.
- To compare the diagnostic outcomes of FNAB samples obtained using varying needle sizes.
Main Methods:
- Retrospective analysis of 699 thyroid FNAB procedures performed between 2018 and 2021.
- Samples were collected using 23-gauge (n=144), 25-gauge (n=335), and 27-gauge (n=220) needles.
- Statistical analysis compared ND rates across different needle gauges and correlated nodule size with ND rates.
Main Results:
- Nondiagnostic (ND) rates were significantly higher with 27-gauge needles compared to 23- and 25-gauge needles (P=.002).
- A significantly lower ND rate was observed with 25-gauge needles versus 27-gauge needles (P=.001).
- Larger thyroid nodule size was associated with a reduced ND rate (OR, 0.801; 95% CI, 0.691-0.929).
Conclusions:
- 25-gauge needles are more effective than 27-gauge needles in minimizing nondiagnostic (ND) rates for thyroid nodule FNAB specimens.
- The findings suggest that needle gauge selection can impact specimen adequacy.
- Further prospective studies are recommended to validate these results.