Related Experiment Video
Updated: Aug 18, 2025

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
Linac primary barrier transmission for concrete: Monte Carlo calculations
1Radiation Oncology Department, Beaumont Health System, Royal Oak, Michigan, USA.
Abstract:
Recent publications have called into question the accuracy of reference tenth-value layer (TVL) data cited in official reports for linac primary concrete barriers. Doubts have arisen based on both experimental and theoretical evidence. Most of the standard reference TVL values trace back to a publication that appeared in 1984 that used beam spectra that are not representative of modern linacs. This study reports a new set of TVL data for concrete based on modern linac beam spectra and a definition of the barrier transmission that is consistent with its use in shielding calculations. TVL values have been computed for concrete using Monte Carlo simulation for beam energies of 4, 6, 10, 15, and 18 MV. The barrier transmission depends on the field size at the barrier and the distance from the distal surface of the barrier to the point of observation. The TVL values reported here lead to barrier transmission values that are up to a factor of 4 larger than those in official reports. The air kerma rate beyond the barrier does not obey an inverse square law as the barrier now acts like a new (non-point) source of radiation. For distance greater than 0.3 m from the distal side of the barrier, inverse square predictions of the air kerma rate are low by up to a factor of 2. The average energy of the transmitted photons declines rapidly for all beam energies with increasing barrier thickness up to a thickness of about 50 cm and then slowly increases with increasing thickness.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Permeability of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Measurement of Air Content in Concrete
The pressure method,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Impact Strength of Concrete