Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Feasibility study using longitudinal bioelectrical impedance analysis to evaluate body water status during fluid
Hwain Jeong1, Inwon Park1,2, Jae Hyuk Lee3,4
1Department of Emergency Medicine, Seoul National University Bundang Hospital, 82, Gumi-Ro 173 Beon-Gil, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 13620, Republic of Korea.
Abstract:
Fluid resuscitation is crucial in the initial management of sepsis; however, little is known about the serial changes and overall distribution of fluids administered into the body. To identify the feasibility of longitudinal bioelectrical impedance analysis during fluid treatment, a preclinical porcine model of Escherichia coli-induced sepsis was used. After sepsis induction, pigs were treated with fluid and vasopressors and monitored for up to 12 h after bacterial infusion or until death. Bipolar electrodes for bioelectrical impedance analysis were attached to the left extremities and measurements were performed every 10 min. Among the 12 subjects, 7 pigs expired during the experiment, and the median survival was 9.5 h. As sepsis progressed with an increase in cumulative fluid balance, R0 [∝ 1/extracellular water (ECW)] decreased, while Ri [∝ 1/intracellular water (ICW)] and ratio of extracellular water to total body water (ECW/TBW) increased. The phase angle constantly decreased throughout the monitoring period, and all non-survivors died when the phase angle decreased by more than 10%. Among the variables, ΔR0 and Δphase angle showed moderate negative correlations, and ΔECW/TBW showed a moderate positive correlation with the hourly fluid balance. Compared to survivors, a greater increase in ΔECW/TBW and a decrease in phase angle were observed in non-survivors over time, with an increase in cumulative fluid balance. Differences in ΔECW/TBW and phase angle emerged at 240 min when the difference in cumulative fluid balance between the two groups (survivors vs non-survivors) exceeded 1000 mL. In conclusion, continuous measurements of bioelectrical impedance analysis in a porcine sepsis model are feasible and may reflect changes in the body water profile during fluid resuscitation.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
05:36Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020