Related Experiment Video
Updated: Aug 18, 2025

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Ionized and non-ionized radiation effects on coronary stent implantation
O Kilicoglu1, M I Sayyed2, U Kara3
1Vocational School of Health Services, Marmara University, Kartal, Istanbul, Turkey; Radiation Laboratory, University of Notre Dame, Notre Dame, IN, 46556-5670, USA.
Abstract:
The purpose of this study is to examine the clinical radiation effects on patients with various stents. Several previous researches focused on the mechanical and physical features of the stents, but there have been few studies that focus on the interaction with radiological and clinical radiation. For stent material analysis, the ANSYS package program was employed. These materials and models are often built in three dimensions for three different types of stents made of three various materials. Estimates of blood pressure and thermal radiation were explored, as were the effects of non-ionizing radiation. Furthermore, the radiation attenuation characteristics of stent samples are investigated. The mass attenuation coefficient values are computed using MATLAB code over a large energy range of 0.015-15 MeV, and the findings are validated using theoretical WinXCom results. To determine the gamma-ray attenuation performances of the studied stent samples, variables such as the mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Zeff), exposure build-up factor (EBF), and energy absorption build-up factor (EABF) are computed. Effective removal cross-sections (ΣR) of stent samples were acquired to determine the capacity of stent samples to stop fast neutrons. Finally, the ability of stent samples to stop charged alpha and proton particles was evaluated utilizing mass stopping power and projected range parameters. The discovery demonstrates that S3 has the best attenuation as well as the best proton, alpha, and gamma radiation attenuation capability.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
12:30Vascular Gene Transfer from Metallic Stent Surfaces Using Adenoviral Vectors Tethered through Hydrolysable Cross-linkers
Published on: August 12, 2014
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Antianginal Drugs: Calcium Channel Blockers and Ranolazine
CCBs, a diverse class that includes dihydropyridines (nifedipine) and diphenylalkylamines (verapamil and diltiazem), exert their effect by blocking calcium channels in cardiac and smooth muscle cells. This...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization IV: Nursing Management
Acute Coronary Syndrome IV: Interprofessional Care