Related Experiment Video
Updated: Aug 18, 2025

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
Published on: January 12, 2022
Computed Tomographic Thickness of Retrobulbar Optic Nerve Is Decreased in Glaucoma Patients and Is Negatively
Cem Evereklioglu1, Duygu Gulmez Sevim1, Fatih Horozoglu1
1Department of Ophthalmology, Erciyes University Medical Faculty, Kayseri, TUR.
Abstract:
Purpose The purpose of the study was to quantitatively measure the width of the retrobulbar optic nerve-sheath complex by computed tomography (CT) in glaucoma and evaluate its relationship with optic nerve changes and visual field loss parameters. Methods Sixty-six eyes of 33 patients with bilateral asymmetric glaucomatous optic nerve damage and 20 eyes of 20 age- and sex-matched control subjects without glaucoma were included. Axial retrobulbar optic nerve-sheath complex was measured by CT in the eyes with advanced glaucomatous damage (group 1); in the fellow eyes of the same patients with moderate glaucomatous damage (group 2); and in control subjects (group 3). Measurements were obtained at three different points: just behind the globe, near the optic canal, and in the middle. Results Mean age and sex distribution between groups were comparable (p>0.05). The mean diameters of the retrobulbar optic nerve at three measurement points in group 1 (4.00±0.42mm, 3.49±0.44mm, 3.18±0.45mm) were significantly (for each, p<0.05) lower when compared with the corresponding points of group 2 eyes (4.24±0.41mm, 3.77±0.47nn, 3.47mm±0.44mm) and normal controls (4.58±0.44mm, 4.15±0.45mm, 3.92±0.48mm). Optic disc changes and visual field parameters were negatively correlated with retrobulbar optic nerve diameter (for each, p < 0.05). Conclusion Radiological alterations of the retrobulbar optic nerve in glaucomatous eyes revealed a decreased optic nerve diameter which correlated with disease severity. Optic nerve dimensions below the lower limit for normal individuals may be considered pathologically reduced and, therefore, CT measurements of the retrobulbar nerve may be additive to the traditional triad of raised intraocular pressure, field defects, and optic disc changes in some cases with opaque optic media preventing the fundus examination or with optic nerve anomalies.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Photoreceptors and Visual Pathways