Related Experiment Video
Updated: Aug 18, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Refractory humeral non-union: treatment with photodynamic intramedullary implant IlluminOss® and internal fixation
Giuseppe Basile1, Stefania Fozzato2, Luca Bianco Prevot3
1Trauma Unit and Emergency Department, IRCCS Galeazzi Orthopedics Institute. basiletraumaforense@gmail.com.
Abstract:
Surgically treated humeral shaft fractures can develop into pseudoarthrosis (PSA). Even if PSA is treated according to the proposed literature, refractory non-union of the humerus can be determined. Due to the rarity of this condition, we report our experience in the management of refractory pseudarthrosis of the humerus at the IRCCS Galeazzi Orthopedic Institute (Milan, Italy). We used internal fixation with plate and screws associated with the implant of the IlluminOss® Photodynamic Bone Stabilization System to increase bone stability and improve anchoring of the implant medium. This combined treatment allowed the consolidation of the complex fracture despite the bone loss, ensuring excellent stability of the fracture stumps and constituting a flexible and stable system with the most favourable biomechanical conditions. An increase in refractory PSA cases is likely in the future, due to a higher incidence of surgically treated humeral shaft fractures than in the past. Further studies on the effectiveness of the combined use of plate and screw and the IlluminOss® system will be indispensable.