Related Experiment Video
Updated: Aug 18, 2025

Comparison of Tobacco Host Cell Protein Removal Methods by Blanching Intact Plants or by Heat Treatment of Extracts
Published on: August 8, 2016
Equivalent processing for pasteurization of a pineapple juice-coconut milk blend by selected nonthermal technologies
Semanur Yildiz1, Ga Young Shin2,3, Beatriz Gonçalves Franco2,4
1Department of Food Engineering, Sakarya University, Serdivan, Sakarya, Turkey.
Abstract:
Identifying equivalent processing conditions is critical for the relevant comparison of food quality attributes. This study investigates equivalent processes for at least 5-log reduction of Escherichia coli and Listeria innocua in pineapple juice-coconut milk (PC) blends by high-pressure processing (HPP), pulsed electric fields (PEF), and ultrasound (US) either alone or combined with other preservation factors (pH, nisin, and/or heat). The two blends (pH 4 and 5) and coconut milk (pH 7) as a reference were subjected to HPP at 300-600 MPa, 20°C for 0.5-30 min; PEF at an electric field strength of 10-21 kV/cm, 40°C for 24 µs; and US at 120 µm amplitude, 25 or 45°C for 6 or 10 min. At least a 5-log reduction of E. coli was achieved at pH 4 by HPP at 400 MPa, 20°C for 1 min; PEF at 21 kV/cm, 235 Hz, 40°C for 24 µs; and US at 120 µm, 45°C for 6 min. As L. innocua showed greater resistance, a synergistic lethal effect was provided at pH 4 by HPP with 75 ppm nisin at 600 MPa, 20°C for 5 min; PEF with 50 ppm nisin at 18 kV/cm, 588 Hz, 40°C for 24 µs; and US at 45°C, 120 µm for 10 min. The total soluble solids (11.2-12.4°Bx), acidity (0.47%-0.51% citric acid), pH (3.91-4.16), and viscosity (3.55 × 10-3 -4.0 × 10-3 Pa s) were not significantly affected under the identified equivalent conditions. HPP was superior to PEF and US, achieving higher ascorbic acid retention and lower color difference in PC blend compared to the untreated sample.
More Related Videos
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Tissue Homogenization and Cell Lysis
Mechanical methods of tissue homogenization
These methods rely on applying external physical force to disrupt...

