A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Early Experience with the Biotronik Protego ICD Lead
Thomas Seiler1, Christian Grebmer1, Gabriela Hilfiker1
1Heart Centre Lucerne, Luzerner Kantonsspital, 6000 Luzern, Switzerland.
Abstract:
Background: In the last decade, newer generation ICD leads have been developed based on mechanistic insides of priorly failing leads. The aim of our study was to assess the long-term performance and mechanisms of failure of the 2013-introduced Biotronik Protego ICD lead in a real-world population. Methods: All patients, who underwent implantation of a Protego ICD lead at the Heart Centre Lucerne (Lucerne, Switzerland) between November 2013 and March 2017, were followed up with semi-annual device-controls. The primary endpoint was defined as lead failure, secondary endpoints compromised all-cause death, (in)appropriate shocks and the need for reintervention. Results: A total of 64 patients (mean age 66.7 ± 8.7 years, 30% female) underwent implantation of a Protego ICD lead: 78% for primary prevention, 53% had underlying ischemic heart disease, and 40.6% had a dilated cardiomyopathy (DCM). Mean left ventricular ejection fraction (LVEF) was 32.6 ± 10.5%. A total of 24 patients were treated with cardiac resynchronization therapy (CRT), and their baseline LVEF improved from 27.8 ± 7.3% before to 39.8 ± 12.5 after implantation (p < 0.001). Mean time to follow-up was 5.5 ± 0.9 years. Overall, 14 patients (26.6%) suffered from at least one episode of sustained ventricular tachycardia; in total 10 patients (15.6%) died. Two patients experienced lead failure due to lead fracture after 5.5 and 5.7 years, which was clinically apparent by an abrupt rise in lead impedance (>2000 Ω) and by repetitive inappropriate shocks, respectively. Conclusions: In this retrospective observational study, the calculated annual lead failure rate of the Biotronik Protego ICD lead was 0.59% per patient—thus, the durability and long-term performance seem to be promising.
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Catheterization I: Pre-Procedure Overview