Evaluating fetal heart morphology in hypertensive disorders of pregnancy using the fetal heart quantitative technique
Fang Tan1, Jiaojiao Yang1, Yuqin Shen2
1Ningxia Medical University Clinical School of Medicine, Yinchuan, China.
Background:
This study sought to explore the clinical application value of fetal heart quantification (HQ) technology in the evaluation of fetal heart morphology in hypertensive disorders of pregnancy (HDP).
Methods:
Fetal HQ software was used to quantitatively analyze the 4-chamber global sphericity index (GSI) and 24-segment sphericity index (SI) and Z scores of 53 normal fetal hearts (the normal group) and 26 fetal hearts with gestational hypertension (the case group). The normal Z value range was set at -2 to 2.
Results:
There was a statistically significant difference between the 1-16 and 20-24 segments of the left and right ventricles in the normal group (P<0.05), but there was no statistically significant difference between the 17-19 segments (P>0.05). There was no statistically significant difference in the fetal GSI between the 2 groups (P>0.05). There was no statistically significant difference in the SI of the 24 segments of the fetal left ventricle between the 2 groups (P>0.05). There was no statistically significant difference in the SI between the 1-20 segments of the right ventricle between the 2 groups (P>0.05), but there was a statistically significant difference in the SI between the 21-24 segments (P<0.05). There was no statistically significant difference in the incorrect ratio of the Z value of the GSI between the 2 groups (P>0.05). There was no statistically significant difference in the abnormal rate of the Z value of the SI in each segment of the fetal left ventricle between the 2 groups (P>0.05). There was a significant difference in the abnormal rate of the Z value of the SI in each segment of the fetal right ventricle between the 2 groups (P<0.05).
Conclusions:
Fetal HQ technology can be used in the quantitative analysis of cardiac morphology in gestational hypertension, and provides a new method for fetal cardiac morphology analysis.