[Application status of CFD technology in occupational hazard control]

Y J Duan1, Y F Ma1, Q D Wu1

  • 1Radiation Health Room of China Institute for Radiation Protection, Taiyuan 030006, China.

Summary

Computational fluid dynamics (CFD) technology aids in mapping workplace hazards for effective occupational disease prevention. This review analyzes CFD applications, limitations, and future research in hazard management.

Related Concept Videos

Hazard Rate01:11

Hazard Rate

The hazard rate, also known as the hazard function or failure rate, is a statistical measure used to describe the instantaneous rate at which an event occurs, given that the event has not yet happened. From a probabilistic perspective, it represents the likelihood that a subject will experience the event in a very small time interval, conditional on surviving up to the beginning of that interval. In terms of frequency, the hazard rate can be viewed as the ratio of the number of events to the...
162
Design Example: Analyzing Capacity Contours for Flood Risk Assessment01:17

Design Example: Analyzing Capacity Contours for Flood Risk Assessment

Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
89
Design Example: Calculating Safe Diameter for Wind-Exposed Disc01:17

Design Example: Calculating Safe Diameter for Wind-Exposed Disc

Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
170
Conservation of Mass in Finite Cotrol Volume01:16

Conservation of Mass in Finite Cotrol Volume

The principle of conservation of mass is a fundamental law in fluid mechanics and is applied using the continuity equation. We apply the concept to a finite control volume to derive the continuity equation.
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
1.4K
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
227
Control Systems: Applications01:25

Control Systems: Applications

Electrical engineering plays a pivotal role in our daily lives, with control systems at the heart of many applications, from home appliances to sophisticated space shuttles. Control systems manage and regulate the behavior of devices and processes, ensuring they function safely, correctly, and efficiently.
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
690