Related Experiment Video
Updated: Aug 17, 2025

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
Long loop technique with bifemoral access as salvage technique for repositioning of dislodged port catheters
Vincent Van den Bosch1, Frédéric De Beukelaer2, Peter Isfort2
1Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany. vvandenbosch@ukaachen.de.
Background:
Repositioning of dislocated port systems' catheters is usually performed with a pigtail catheter and/or a goose snare. In case of an inaccessible port catheter tip due to thrombosis, this classic approach may be not successful. For these cases, we describe a long loop bailout technique with bifemoral access.
Technique:
Via a right transfemoral access, a first attempt to reposition the dislodged port catheter using pigtail catheter and goose snare was performed. After an unsuccessful attempt and delineation of thrombosis of the catheter tip, the contralateral femoral vein was subsequently punctured and a sheath was placed. Through both vascular sheaths, pigtail catheter and goose wire were advanced distally to the catheter. The guidewire in the pigtail catheter was snared, thus creating a "Long loop" configuration. Pulling down both catheters simultaneously with improved stability allowed to detach the catheter tip from the vessel wall and replacement into the superior vena cava was possible. Refinement of catheter tip position was done using the goose snare. This technique was applied on 5 patients with dislodged port catheters in the jugular vein (2/5), the innominate vein (1/5), the subclavian vein (1/5) and the azygos vein (1/5) with a technical success of 100%. No complications were observed.
Conclusion:
The Long loop technique can be used as salvage approach to reposition a dislodged catheter in case of failure with pigtail catheter and goose snare.