Related Experiment Video
Updated: Aug 17, 2025

Environmental Dynamic Mechanical Analysis to Predict the Softening Behavior of Neural Implants
Published on: March 1, 2019
Does thermoplastics' thickness influence joint stabilization and movement coordination? An inferential study of wrist
Pedro H T Q de Almeida1,2, Bruno Batista Santos3, Lilian Dias Bernardo4
1Department of Occupational Therapy, Boston University, Boston, MA, USA.
Background:
Given the existence of multiple low-temperature thermoplastics, clinicians fabricating can readily modify an orthoses' thickness, weight and flexibility, among other properties. However, there is limited evidence on the impact of such different materials on upper extremities' biomechanics.
Objective:
Our study aimed to investigate differences in joint stabilization and movement coordination provided by upper extremity orthotics fabricated with low-temperature thermoplastics of different thicknesses.
Study Design:
Inferential, cross-sectional study.
Method:
We conducted a kinematic analysis of a standardized task through a three-dimensional motion capture system. Ten participants (5 female) performed the same task under three circumstances: 1) wearing a volar wrist immobilization orthosis, made with a 3.2-mm thick low-temperature thermoplastic; 2) using the same orthotic fabricated with a 1.6-mm thick material; and (3) without orthoses. We divided the standardized task into five logical phases for data analysis, obtaining the active range of motion of the shoulder, elbow, forearm, and wrist joints as the primary outcome. Secondary outcomes included movement smoothness and coordination, measured by the number of motor units, time, and distance travelled by the upper extremity.
Results:
Despite changes in thermoplastic thickness, both orthotics significantly restricted the wrist motion during task performance (F(2,16) = 14.32, P < .01, and η2p = 0.797), with no difference between the 2 devices and no significant changes to proximal joints' active range of motion. Although orthoses use increased the time required for task performance (F(2,16) = 23.05, P < .01, and η2p = 0.742), no significant differences in movement smoothness or coordination were noted.
Conclusion:
Our results indicate that wrist orthoses fabricated with a 1.6-mm thick low-temperature thermoplastic can provide joint stabilization similar to a device made from a 3.2-mm thickness material, suggesting thinner thermoplastics' efficacy to stabilize joints in the absence of contractures or preexisting chronic conditions.
Related Concept Videos
Plastic Deformation in Circular Shafts
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
Members Made of Elastoplastic Material
As the bending moment...
Circular Shafts - Elastoplastic Materials
As torque on the...
Plastic Deformations

