Effects of the conventional, soft start, and pulse delay modes produced by light-emitting diode device on
Yasser Munther Najjar1, Ahmad S Burhan1, Mohammad Y Hajeer1
1Department of Orthodontics, University of Damascus Dental School, Damascus, Syria.
Background:
This study aimed to evaluate microleakage beneath metal brackets cured by different light curing modes.
Materials And Methods:
Sixty extracted human premolars were randomly divided into three groups according to the light curing mode. Metal brackets were bonded in all groups according to the manufacturer's recommendations with a light-emitting diode device. Light curing was applied as follows: group 1: conventional mode (10 s mesial+10 s distal); group 2: soft start mode (15 s mesial+15 s distal); group 3: pulse delay mode (3 s mesial+3 s distal, followed by 3min of no photoactivation, then 9 s mesial+9 s distal). Radiant exposure was the same in all study groups. After curing, the teeth were incubated at 37 degrees for 24hours, then thermocycled 500 times. Next, they were sealed with nail varnish, immersed in methylene blue 1% for 24hours, sectioned, and examined under a stereomicroscope. Microleakage was measured at both enamel-adhesive and bracket-adhesive interfaces, and the total microleakage for each tooth was computed. Statistical analyses were performed using Kruskal-Wallis and Welch test for comparing microleakage among groups. Wilcoxon signed ranks test was used for comparing microleakage between the bracket-adhesive and enamel-adhesive interfaces.
Results:
There was no significant difference in microleakage at the bracket-adhesive interface among study groups. At the enamel-adhesive interface and total microleakage, the pulse delay group exhibited significantly lower microleakage than the conventional group. Whereas there was no significant difference between the soft start group and other study groups. In all study groups, microleakage at the enamel-adhesive interface was greater than that at the bracket-adhesive interface.
Conclusion:
The pulse delay mode caused lesser microleakage than the conventional mode. This supports the use of this mode in orthodontic bonding.