Related Experiment Video
Updated: Aug 17, 2025

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Evaluation of measures related to dosimetric uncertainty of VMAT plans
Julia Götstedt1,2, Anna Karlsson1,2, Anna Bäck1,2
1Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Abstract:
Dosimetric uncertainty is most often not included in the process of creating and selecting plans for treatment. Treatment planning and the physician's choice of treatment plan is instead often based only on evaluation of clinical goals of the calculated absorbed dose distribution. Estimation of the dosimetric uncertainty could potentially have impact in the process of comparing and selecting volumetric modulated arc therapy (VMAT) plans. In this study, different measures for estimation of dosimetric uncertainty based on treatment plan parameters for plans with similar dose distributions were evaluated. VMAT plans with similar dose distributions but with different treatment plan designs were created using three different optimization methods for each of ten patient cases (tonsil and prostate cancer). Two plans were optimized in Eclipse, one with and one without the use of aperture shape controller, and one plan was optimized in RayStation. The studied measures related to dosimetric uncertainty of treatment plans were aperture-based complexity metric analysis, investigation of modulation level of multi leaf collimator leaves, gantry speed and dose rate, quasi-3D measurements and evaluation of simulations of realistic delivery variations. The results showed that there can be variations in dosimetric uncertainty for treatment plans with similar dose distributions. Dosimetric uncertainty assessment could therefore have impact on the choice of plan to be used for treatment and lead to a decrease in the uncertainty level of the delivered absorbed dose distribution. This study showed that aperture shape complexity had a larger impact on dosimetric uncertainty compared to modulation level of MLC, gantry speed and dose rate.
More Related Videos
Related Concept Videos
Propagation of Uncertainty from Systematic Error
Uncertainty: Overview
Uncertainty in Measurement: Accuracy and Precision
Uncertainty in Measurement: Reading Instruments
Propagation of Uncertainty from Random Error
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...