Related Experiment Video
Updated: Aug 17, 2025

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
A Novel Method for Estimating Right Atrial Pressure With Point-of-Care Ultrasound
Larry Istrail1, Joseph Kiernan2, Maria Stepanova1
1Department of Medicine, Inova Fairfax Hospital, Falls Church, Virginia.
Background:
Current noninvasive estimation of right atrial pressure (RAP) by either bedside jugular venous pressure exam or inferior vena cava measurement during a comprehensive echocardiogram offers imprecise estimates of actual RAP.
Methods:
We enrolled 41 patients in a prospective, blinded study to validate a novel point-of-care ultrasound method using direct right atrial depth (RAD) measurement and jugular venous ultrasound to estimate RAP. Two subjects were excluded, and 39 were included in the final analysis. A parasternal long-axis view was obtained, and the depth of the noncoronary cusp attachment to the posterior left ventricular outflow tract was recorded as the RAD. This was added to an estimate of the jugular venous pressure obtained during a jugular vein ultrasound to calculate an estimated RAP (RAPUS). The RAPUS was compared to the RAP measurement during right heart catheterization (RAPcath) both as measured and as corrected for where the catheter was zeroed.
Results:
The correlation coefficient between RAPcath and RAPUS was +0.75; regression R2, 0.56; and bias, -0.49 mm Hg (95% CI, -1.42 to +0.43 mm Hg), with the limits of agreement -5.56 to +7.24 mm Hg and accuracy of 3 mm Hg or less in 29 (74%) of the subjects. For the RAPUS corrected for the catheter zero point, the correlation coefficient between RAPcath and RAPUS was +0.72; regression R2, 0.52; and bias, -0.60 mm Hg (95% CI, -1.60 to +0.39 mm Hg), with the limits of agreement -5.56 to +7.24 mm Hg and accuracy of 3 mm Hg or less in 26 (67%) of the subjects.
Conclusion:
This simple ultrasound evaluation of RAD and the right jugular vein correlates well with actual RAP and can accurately estimate RAP within 3 mm Hg in most patients. This has the potential to improve our bedside volume status exam, as well as improve the accuracy of RAP estimation during comprehensive echocardiogram.
More Related Videos
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
07:41Induction and Phenotyping of Acute Right Heart Failure in a Large Animal Model of Chronic Thromboembolic Pulmonary Hypertension
Published on: March 17, 2022
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Catheterization II: Right Heart Catheterization
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: