Related Experiment Video
Updated: Aug 17, 2025

Plasma-assisted Molecular Beam Epitaxy of N-polar InAlN-barrier High-electron-mobility Transistors
Published on: November 24, 2016
Terahertz direct polarization detector based on integrated antenna-coupled AlGaN/GaN high-electron-mobility
Abstract:
The foundation for polarization-based terahertz applications is the acquisition of polarization information. To develop an all-electronic terahertz straightforward polarization detection system, in this paper, a terahertz polarization detector based on three antenna-coupled AlGaN/GaN high-electron-mobility transistors (HEMTs) on a single chip is designed and fabricated. The function of the direct polarization detector is proven by measuring the polarization angle of linearly polarized continuous-wave terahertz radiation at 216 GHz. The average deviation and maximum deviation of the measured polarization angle are 3.7 degrees and 10 degrees, respectively. The error comes mainly from the disturbance of the local terahertz field by the interference effect. Simulations locate the sources of interference and guide the further device design and packaging of such kind of direct polarization detectors.