Related Experiment Video
Updated: Aug 13, 2026

Isolation of Human Atrial Myocytes for Simultaneous Measurements of Ca2+ Transients and Membrane Currents
Published on: July 3, 2013
Beat-to-beat changes in atrioventricular nodal excitability and its modulation by concealed conduction during
1Electrophysiology Laboratory, Wayne State University, Detroit, MI.
Abstract:
An atrial pacing model of functional 2:1 block was used in 10 patients to investigate for the first time the electrophysiologic properties of the human atrioventricular node during intermittent conduction. By varying the terminal portion of the 2:1 atrial train and using the extrastimulus technique, we characterized atrioventricular nodal (AVN) conduction and refractoriness after five different methods of AVN activation: a conducted beat (method I), a conducted beat with omission of the prior blocked beat (method II), a blocked beat (method III), a blocked beat "converted" to one that conducts by omission of the prior conducted beat (method IV), and finally, 1:1 conduction at twice the cycle length of the 2:1 train (control method V). Observed AVN conduction times obeyed the following relationship: method I greater than method II greater than method V, indicating a cumulative effect of concealed penetration by the blocked beats. During 2:1 block, the AVN effective refractory period (ERP) alternated with a mean beat-to-beat difference of at least 100 msec, due mostly to marked ERP abbreviation during AVN activation by method III (vs both 2:1 train cycle length and activation by method V). Concealed penetration by the blocked beat prolonged AVN ERP for the propagated beat (vs that with methods II and V), but to a lesser extent than conduction time was increased. Moreover, the AVN recovery curve with method I was displaced upward and to the right compared with that with methods II to V.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Dysrhythmias IV: Characteristics of Bradyarrhythmias

