Related Experiment Video
Updated: Aug 17, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Proposal of a diagnostic algorithm based on the use of pulse oximetry in obstructive sleep apnea
Eduardo Borsini1, Carlos Alberto Nigro2
1Sleep and Ventilation Unit, Buenos Aires Hospital Británico, 74 Perdriel, Buenos Aires, Argentina. borsinieduardo@yahoo.com.ar.
Purpose:
The aims of this study were to assess the cut-off values for oxygen desaturation index ≥ 3% (ODI3) to confirm obstructive sleep apnea (OSA) in subjects undergoing polysomnography (PSG) and home-based respiratory polygraphy (RP), and to propose an algorithm based on pulse oximetry (PO) for initial management of patients with suspected OSA.
Methods:
This was an observational, cross-sectional, retrospective study. ODI3 was used to classify subjects as healthy (no OSA = AHI < 5 or < 15 events/h) or unhealthy (OSA = AHI ≥ 5 or ≥ 15 events/h). On the PSG or experimental group (Exp-G), we determined ODI3 cut-off values with 100% specificity (Sp) for both OSA definitions. ODI3 values without false positives in the Exp-G were applied to a validation group (Val-G) to assess their performance. A strategy based on PO was proposed in patients with suspected OSA.
Results:
In Exp-G (PSG) 1141 patients and in Val-G (RP) 1141 patients were included. In Exp-G, ODI3 > 12 (OSA = AHI ≥ 5) had a sensitivity of 69.5% (CI95% 66.1-72.7) and Sp of 100% (CI95% 99-100), while an ODI3 ≥ 26 had a 53.8% sensitivity (CI95% 49.3-58.2) and Sp of 100% (CI95% 99.4-100) for AHI ≥ 15. A high pretest probability for OSA by Berlin questionaire (≥ 2 categories) had a lower diagnostic performance than by STOP-BANG questionnaire ≥ 5 points (AHI ≥ 5: 0.856 vs. 0.899, p < 0.001; AHI ≥ 15: 0.783 vs. 0.807, p 0.026).
Conclusion:
We propose the initial use of PO at home in cases of moderate-to-high pretest probability of OSA. This algorithm considers PO as well as RP and PSG for more challenging cases or in case of doubt.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Sleep Apnea
The condition is more prevalent among...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

