Related Experiment Video
Updated: Aug 17, 2025

Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model
Published on: February 23, 2020
Aortic diameter is a poor predictor of aortic tissue failure metrics in patients with ascending aneurysms
Emily Vianna1, Benjamin Kramer1, Samar Tarraf2
1Department of Thoracic and Cardiovascular Surgery, Aorta Center, Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, Ohio.
Objectives:
There is growing consensus that aortic diameter is a flawed predictor of aortic dissection risk. We hypothesized that aortic tissue metrics would be better predicted by clinical metrics other than aortic diameter. Our objectives were to (1) characterize circumferential aortic failure stress and stretch as a result of aortic size and patient demographics, and (2) identify the influence of bicuspid aortic valve on failure metrics.
Methods:
From February 2018 to January 2021, 136 aortic tissue samples were obtained from 86 adults undergoing elective ascending aorta repair. Uniaxial biomechanical testing to failure, defined as a full-thickness central tear, was performed to obtain tissue failure stress and failure stretch and compared with clinical data and preoperative computed tomography imaging. The relationships among aortic diameter, patient demographics, and failure metrics were assessed using random forest regression models.
Results:
Median failure stress was 1.46 (1.02-1.94) megapascals, and failure stretch was 1.36 (1.27-1.54). Regression models correlated moderately with failure stress (R2 = 0.557) and highly with failure stretch (R2 = 0.806). Failure stress decreased with increasing age, lower body mass index, thicker tissue, and tricuspid aortic valves, whereas failure stretch was most highly correlated with age. Aortic area-to-height index outperformed aortic diameter in all models.
Conclusions:
Aneurysmal ascending aortic tissue failure metrics correlated with available clinical metrics. Greater tissue thickness, older age, and tricuspid aortic valve morphology outperformed aortic diameter, warranting further investigation into the role of a patient-specific multifactorial dissection risk assessment over aortic diameter as a sole marker of aortic tissue integrity.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...