A Friend in Need Is a Friend Indeed? Analysis of the Willingness to Share Self-Produced Electricity During

Konstantin Kurz1, Carolin Bock1, Michèle Knodt2

  • 1Chair of Entrepreneurship, Department of Law and Economics, Technical University of Darmstadt, Hochschulstr. 1, 64289 Darmstadt, Germany.

Schmalenbachs Zeitschrift Fur Betriebswirtschaftliche Forschung = Schmalenbach Journal of Business Research
|December 19, 2022
PubMed

Related Concept Videos

Conservation of AC Power01:15

Conservation of AC Power

The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
375
Electrical Power01:07

Electrical Power

Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
158
Distribution Reliability and Automation01:25

Distribution Reliability and Automation

Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
145
Electrical Energy01:10

Electrical Energy

Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.3K
Power in an AC Circuit01:26

Power in an AC Circuit

In a DC circuit, the power consumed is simply the product of the DC voltage times the DC current, given in watts. However, the power consumed for AC circuits with reactive components is calculated differently. Since electrical power is the "rate" at which energy is used in a circuit, all electrical and electronic components and devices have a safe operating range for electrical power.
In a DC circuit, there is no sinusoidal waveform associated with the supply; the voltages and currents...
2.1K