Related Experiment Video
Updated: Aug 16, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
An X-ray lead screen may be used to reduce an interventional radiologist's radiation exposure during CT-guided
Grzegorz Rosiak1, Joanna Podgórska1, Krzysztof Milczarek1
1II Department of Radiology, Warsaw Medical University, Warsaw, Poland.
Purpose:
The exposure of both patient and operator to radiation is one of the limitations of computed tomography (CT)-guided interventions, and it should be kept as low as reasonably possible. The purpose of the study was to evaluate the efficacy of a lead screen in reducing the radiation dose to an operator in the course of CT-guided interventions.
Material And Methods:
This prospective study analysed data collected from 72 consecutive CT-guided procedures, all of which were performed with an X-ray protective lead screen placed between the scanner and the operator. Five dosimeters were placed in the CT scanning room, and accumulated radiation doses were measured for each dosimeter.
Results:
The dosimeter placed on the gantry side of the lead screen revealed highest levels of radiation (11.33 ± 1.93 mSv), which were significantly higher than those at all other dosimeters. The radiation dose behind the lead screen was almost the same when measured by dosimeters on the CT scanner gantry side and 3 metres away from it. The presence of the screen caused no discomfort for operators.
Conclusions:
A lead screen reduces an operator's radiation exposure significantly, while not posing any obstacles or causing any discomfort while CT-guided procedures are carried out.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
X-ray Imaging