Isothermal inactivation of Mycobacterium avium subsp. paratuberculosis in curd simulating the stretching phase in

Filippo Barsi1, Elena Dalzini2,3, Simone Russo1

  • 1National Reference Centre and WOAH Reference Laboratory for Paratuberculosis, Istituto Zooprofilattico Sperimentale della Lombardia e dell'Emilia Romagna "Bruno Ubertini", Piacenza, Italy.

Frontiers in Microbiology
|December 19, 2022
PubMed

Insights

This study determined the thermal inactivation of Mycobacterium avium paratuberculosis (MAP) in cheese curd. Findings provide critical data for ensuring food safety in pasta-filata cheese production.

Area of Science:

  • Food Science
  • Microbiology
  • Food Safety

Background:

  • Raw milk and dairy products are primary sources of Mycobacterium avium subsp. paratuberculosis (MAP) exposure.
  • The curd stretching step in pasta-filata cheese production is critical for MAP inactivation.

Purpose of the Study:

  • To determine the thermal death time values of MAP directly within cheese curd.
  • To establish inactivation kinetics of MAP during pasta-filata cheese processing.

Main Methods:

  • Inoculation of milk with MAP strains, followed by curd preparation.
  • Vacuum packing and thermal treatment of contaminated curd samples at temperatures ranging from 60°C to 75°C.
  • Evaluation of MAP survival using plate counts and estimation of inactivation parameters (D-values, z-value).

Main Results:

  • D-values for MAP in curd ranged from 0.15 min (at 75°C) to 4.22 min (at 60°C).
  • The calculated z-value was 10.2°C, indicating thermal resistance in curd.
  • Established inactivation kinetics for MAP in the specific matrix of pasta-filata cheese curd.

Conclusions:

  • The study provides essential data for designing safe thermal processes for pasta-filata cheese.
  • Results aid in predicting time/temperature combinations for effective MAP reduction during curd stretching.
  • Optimized validation of cheese-making processes to control MAP contamination is facilitated.

Related Concept Videos

Physical Methods for Controlling Microbial Growth: Temperature01:23

Physical Methods for Controlling Microbial Growth: Temperature

Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
183
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
181
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
20.5K
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
6.8K